Water Pressure Requirements for Sensor Sanitary Ware
What are the water pressure requirements for sensor sanitary ware? The opera
Read moreModel | GBL-6712A |
Input Voltage | AC 220 V |
Output Voltage | DC12V |
Sensor Operating Voltage | DC 12V |
Maximum Sensor Detection Radius | 6 m |
Detection Angle | Horizontal 110°, Vertical 26° |
Operating Water Pressure | 0.05–0.7 MPa |
Solenoid Valve DN | Inlet: DN25, Outlet: DN25 |
Flush Time | 10 s |
Sensor Sensitivity | 1 Second |
Operating Temperature | 1–40°C |
Ambient Humidity | Below 95% RH |
Automatic Sensor, Smart Management
Microcontroller-based fully automatic intelligent control for precise management: more flushes with higher traffic, fewer flushes with lower traffic, and no flush when unoccupied.
Universal Sensor Head – Full Coverage
The adjustable universal sensor offers a maximum detection range of 6 meters, with 30° vertical and 110° horizontal coverage. It rotates front, back, left, and right to precisely target your optimal sensing zone.
Human-Centric Design for Hygiene and Practicality:
Upon each power restoration after an outage, the system immediately initiates a self-check and triggers a mandatory flush to ensure hygienic conditions.
Reliable Performance, 10-Year Warranty:
Microcomputer control technology requires no batteries and ensures that programs are never lost under any circumstances. The system is designed to industrial standards, with a service life of over 10 years, and comes with a one-year free warranty.
Safe to Use, Easy to Install:
Output voltage: 12V, compliant with national safety standards. Installation height of 2.4m prevents user contact and eliminates safety risks while protecting against vandalism. No in-wall pre-embedded components required; standard plumbing and electrical installation takes approximately 2 hours.
Zero Risk, High Return:
Water savings of up to 60%–90%, with a return on investment (ROI) ratio of 1:15, enabling full payback within 1 to 3 months.
The forced shower controller uses a curtain-type infrared detection method with a wide horizontal detection angle and a narrow vertical detection angle. Installed on the ceiling or sides corresponding to the passage, with the detection window aligned to the passage, it accurately detects passing personnel to prevent false activation. The detector is connected to the controller via a three-core sheathed cable. The wires inside the sheath are red, black, and blue, which connect respectively to the terminals marked red, black, and blue on the controller’s terminal block.
Upon first power-on, the sensor-activated forced shower controller enters a self-check mode lasting approximately 1 minute.
Verify that the wiring is correct (incorrect wiring may cause damage to the device);
Turn on the power switch; the power indicator light will illuminate. At this point, regardless of whether the infrared sensor detects a person, the indicator light remains on and the unit performs one cycle with a 60-second water flow (this step is designed for system self-check).
Once the cycle ends and the indicator light turns off, the system returns to normal operation. The water-fill indicator illuminates only when a person enters the infrared detection range;
Press the manual button. Regardless of the current system state, the solenoid valve will open immediately to begin water filling. Once the preset fill time elapses, the solenoid valve closes and stops the flow, confirming that the system is operating correctly.
The distance between the shower and the detection zone shall not exceed 3 meters;
For optimal performance, mount the sensor on both sides of the corridor at a height of 2.4 m or above.
Install a U-bend at the shower head inlet, ensuring that the horizontal position of the shower head inlet hose is higher than the solenoid valve outlet pipe to achieve maximum flow speed.
The controller is equipped with a general-purpose DC-12V inline solenoid valve featuring superior anti-clogging performance and tool-free cleaning. To ensure the valve’s service life, a filter is installed at the inlet of the solenoid valve body. Users can periodically remove and clean the filter based on local water quality conditions; it is recommended to perform this maintenance every 3–6 months.
To ensure the service life of the solenoid valve, flush the pipelines to remove debris before installation and verify that no impurities remain. After installing the solenoid valve, perform a pressure test on the pipeline system to confirm there are no leaks at any point, which could affect normal operation. The sensor should not be installed outdoors, in areas with pets, under direct sunlight, or beneath rotating objects. Avoid obstructions that may block detection; adjust the horizontal detection angle as needed to prevent blind spots, and modify the probe orientation if necessary.
Do not touch the detector window surface. To clean the sensor lens, disconnect the power supply and gently wipe with a soft cloth dampened with a small amount of alcohol.