Water Pressure Requirements for Sensor Sanitary Ware
What are the water pressure requirements for sensor sanitary ware? The opera
Read moreThe urinal sensor operates on the same infrared reflection principle as sensor faucets and sensor squat pans. When a person enters the detection range, the IR emitter transmits a signal that is reflected by the body and captured by the IR receiver. The microcontroller processes this reflected signal and sends an open/close water command to the solenoid valveSolenoid Valve EN 15091to enable automatic flushing. The urinal flushes only when a person is detected within the sensor range; otherwise, no flush occurs. Flush programs, duration, and detection distance are adjustable via the MCU or through GIBO’s dedicated infrared sanitary ware remote control—making it the optimal choice for smart, water-saving public restrooms. As a touchless, water-saving solution that requires no manual operation, the urinal sensor effectively prevents cross-contamination of bacteria, making it ideal for high-traffic public facilities such as schools, railway stations, airports, and bus terminals.
1. Smart Water-Saving: The urinal sensor intelligently selects between single and dual flush modes based on usage frequency to effectively prevent water waste. During high-frequency use, a single-stage flush (Stage I: 2 seconds) is executed; during low-frequency use, a dual-stage flush (Stage II: 7 seconds) is triggered.
2. Hygienic and Convenient: The touchless urinal automatically activates flushing, ensuring thorough rinsing with no lingering odors—effectively preventing cross-contamination by bacteria.
3. Automatic Range Adjustment: The ultra-compact circuit design, controlled by a microcomputer, automatically adjusts the sensor range of the urinal sensor based on the working environment, eliminating the need for manual calibration.
4. Smart Odor Prevention: If the urinal remains unused for an extended period, the flush valve automatically activates every 24 hours to prevent evaporation of water in the P-trap, thereby blocking odor backflow.
5. Easy Maintenance: Built-in flow control valve and filter screen allow non-professionals to easily adjust water flow and clean the filter.
6. Installation Features: Concealed installation design, suitable for walls with a thickness of 12 cm.
7. Smart Power Saving: GIBO’s advanced sensor technology ensures faster, more responsive detection. Powered by a low-power chip with a built-in energy-saving mode, it delivers ultra-low consumption for greater efficiency (DC models use 4 AA alkaline batteries with a standby current of ≤30μA).
8. Low-voltage alert: When battery voltage drops below 4.6V, the red indicator flashes to prompt battery replacement.
9. Power supply options: AC, DC, or dual AC/DC. The dual AC/DC mode enables automatic soft switching.
Power Supply: DC 6V
Static power consumption < 60 μA
Battery life: 1.5 years (based on 200 uses per day)
Sensor detection range: factory-set at 80 cm
Inlet Hose Connection Size G1/2″(DN15)
Operating water pressure: 0.05 MPa – 0.7 MPa
Rated flow rate: 2–5 L/cycle (at water pressure of 0.1 MPa)
Operating temperature: 1–40°C
Operating Humidity: ≤ 95% RH
| Urinal Sensor Installation Diagram | Urinal Sensor Installation Diagram | Urinal Sensor Concealed Mounting Box |
| ![]() | ![]() |